We offer a complete suite of HLA typing solutions,
integrating diverse molecular techniques including NGS, Sanger Sequencing (SBT), and Real-Time PCR kits
HLA Typing Kits (Ultra-High Throughput NGS Technology Solution)






Universal compatibility across all major NGS platforms.
HLA Typing (Short Reads & full length)
"Our product design philosophy is centered on three core pillars:
Operational Simplicity, High Accuracy, and Cost-Effectiveness.
We offer a comprehensive HLA NGS solution featuring two distinct strategies:
- HLA Full-Length Gene Sequencing: Providing complete genomic coverage.
- Short-read Multiplex PCR Amplification: Ideal for standard NGS platforms.
Both solutions are engineered for broad compatibility across multiple mainstream NGS platforms as well as the Oxford Nanopore sequencing platform."
HLA Typing Sanger Sequencing (SBT)
Sanger Sequencing for HLA Typing
The industry-standard method for confirming HLA genotypes. It delivers:
Proven Reliability: Validated by decades of use in reference labs worldwide."
High Confidence: Essential for clinical transplantation decisions.
Unambiguous Results: Clear, single-base resolution.
HLA QPCR Typing Kits
"Introducing our HLA Full-Length Sequencing Solution:
Platform Versatility: Optimized for all NGS systems and fully validated on Oxford Nanopore and other long-read platforms."
Precise & Comprehensive Data: Provides the definitive resolution required for cutting-edge HLA research and clinical association studies.
Complete Genomic View: Captures the entire HLA gene, including all exons and introns, from start to finish.
HLA NGS Full Automatic Work Station
By Precision, For Simplicity
1. Product Overview
The A8 Series NGS Workstation integrates online PCR and quantification modules to achieve full-process automation of library preparation.
2. Performance Data
Our automated workflow delivers superior yield and consistency compared to manual methods.
Fragment Analysis
The fragment distribution profile of the A8-NGS libraries is consistent with manual preparation, with the main peak concentrated between 200–300 bp.
3. Technical Specifications
Feature- Dimensions (W×D×H). Throughput
A8Pro (Low Throughput) 790 × 740 × 980 mm 1 – 24 samples
A8Pro (Mid Throughput) 1240 × 740 × 980 mm 1 – 96 (or 48) samples
A8Plus (High Throughput) 1240 × 740 × 1168 mm 1 – 96 samples
Robotic Pipetting
Principle: Air displacement
Volume: 1 μL – 1000 μL
Accuracy: ±4% @ 5 μL; ±1% @ 200 μL
Precision (CV): ≤4% @ 5 μL; ≤1% @ 200 μL
Liquid Level Detection: Pressure sensing
Safety & Biosafety
UV Sterilization: Dosage > 100,000 μW·s/cm²
HEPA Filter: Efficiency ≥ 99.99% @ 0.3 μm (ISO Class 5 cleanroom standard)
Integrated PCR
Capacity: 96 wells
Speed: Heating ≥ 4°C/s; Cooling ≥ 2°C/s
Uniformity: ≤ 0.2°C
Accuracy: ≤ ±0.3°C
Built-in Quantification
Method: Fluorometric assay
Sensitivity: 0.01 ng/μL
Range: 0.1 – 120 ng/μL
Speed: ≤ 5 seconds/sample
Thermal Shaking
Temp. Range: 4°C – 120°C
Shaking Speed: Up to 3000 rpm
Positioning Accuracy: ±0.1 mm
4. Configurations
A8Plus High: Fixed 96-channel pipette + Flexible 4-channel + Gripper
A8Pro Mid: Fixed 24-channel pipette + Flexible 2-channel + Gripper
A8Pro Low: Fixed 8-channel pipette + Flexible 2-channel + Gripper
In-Situ Purification: Perform purification directly on PCR plates without tube transfer, reducing sample loss.
Pre-set Protocols: Ready-to-use templates minimize setup time.
One-Click Start: Supports direct loading of original sample tubes, simplifying the preparation workflow.

Full automatic NGS Work flow Video is available online 👇



A 8 Full automatic NGS workflow Robot
By Precision, For Simplicity
The A8 Series NGS Workstation integrates online PCR and quantification modules to achieve full-process automation of library preparation.
HLA Sanger Sequencing Technology
HLA SBT Typing Kit
Sanger Sequencing HLA Typing Kits
Our product line covers:
- HLA Class II: Exon 1 through 3
- HLA Class I: Exon 1 through 5
- 3SP technology, which provides a definitive solution to eliminate phase ambiguity and ensure accurate allele assignment.
We supply Sequence-Based Typing (SBT) HLA high-resolution Typing kits.


"Our automated SBT system streamlines the complex manual steps, significantly reducing hands-on time."
Automatic Nucleic Acid Purification
Sanger sequencing automates the labor-intensive nucleic acid purification steps, effectively liberating technicians from repetitive manual tasks.
This automation reduces operational costs and reagent consumption, while simultaneously minimizing human error to ensure consistent data quality.
utomated Sanger Sequencing Benefits:
Error Minimization: Eliminates variability caused by manual handling.
Cost Reduction: Lowers reagent costs and overall operational expenses.
Labor Saving: Automates complex nucleic acid cleanup, freeing up technician time.



Kir Gene Typing Kits NGS
Next-Generation Sequencing for High-Resolution KIR Genotyping
Move beyond basic presence/absence testing with our targeted amplicon-based solution, purpose-built for advanced characterization of Killer-cell Immunoglobulin-like Receptor (KIR) genes — key regulators of NK cell function in transplantation, disease association, and immunology research.
Key Features
✅ Comprehensive Locus Coverage: Captures all 14 functional KIR genes + 2 pseudogenes (KIR2DP1, KIR3DP1) across the chromosome 19q13.4 leukocyte receptor complex, spanning both inhibitory and activating loci.
✅ Allele-Level Resolution: Detects gene content variation and fine-scale allelic diversity, including common variants of KIR2DL5, KIR2DS4, and KIR3DP1.
✅ Flexible Configuration: Choose a full KIR gene panel or individual single-gene assays to match your lab’s throughput and research needs.
✅ Streamlined NGS Workflow: Gene- and variant-specific primers enable efficient library prep with minimal optimization, compatible with standard short-read NGS pipelines.
Ideal For
Immunogenetics studies | Hematopoietic stem cell transplantation (HCT) research | NK cell biology | Population genetics & disease association studies

HLA NGS Typing Service
HLA Typing Service
HLA Typing Services
We provide high-resolution, deep sequencing HLA typing services tailored to your research and clinical needs.
Turnaround Time: We guarantee a rapid turnaround, delivering matched typing results within 5 business days.
Please contact us to request a quote or to discuss your specific project requirements."
Sanger Confirmation: Sanger Sequencing-based HLA typing is available for confirmatory and validation purposes.
Standard High-Res Typing: We offer comprehensive coverage of HLA Class I (Exon 1–5) and HLA Class II (Exon 1–3).
Custom Solutions: Upon request, we also provide--
HLA Full-Length Gene Sequencing to capture all exons and introns.
Superior Biotechnology Meets laboratory Excellence

Get in touch
E-mail: info@geno-code.com
whatsapp: +447404914814
Address : Suite G04, 1 Quality Court, Chancery Lane,
London WC2A 1HR, United Kingdom