We offer a complete suite of HLA typing solutions,
integrating diverse molecular techniques including NGS, Sanger Sequencing (SBT), and Real-Time PCR kits

HLA Typing Kits (Ultra-High Throughput NGS Technology Solution)

Universal compatibility across all major NGS platforms.

HLA  Typing  (Short Reads & full length)

"Our product design philosophy is centered on three core pillars: 

Operational Simplicity, High Accuracy, and Cost-Effectiveness.

We offer a comprehensive HLA NGS solution featuring two distinct strategies:

  1. HLA Full-Length Gene Sequencing: Providing complete genomic coverage.
  2. Short-read Multiplex PCR Amplification: Ideal for standard NGS platforms.

Both solutions are engineered for broad compatibility across multiple mainstream NGS platforms​ as well as the Oxford Nanopore sequencing platform."

HLA Typing Sanger Sequencing (SBT)

Sanger Sequencing for HLA Typing

The industry-standard method for confirming HLA genotypes. It delivers:

Proven Reliability:​ Validated by decades of use in reference labs worldwide."

High Confidence:​ Essential for clinical transplantation decisions.

Unambiguous Results:​ Clear, single-base resolution.

HLA QPCR Typing Kits

"Introducing our HLA Full-Length Sequencing Solution:

Platform Versatility:​ Optimized for all NGS systems and fully validated on Oxford Nanopore​ and other long-read platforms."

Precise & Comprehensive Data:​ Provides the definitive resolution required for cutting-edge HLA research and clinical association studies.

Complete Genomic View:​ Captures the entire HLA gene, including all exons and introns, from start to finish.

HLA NGS Full Automatic Work Station

By Precision, For Simplicity

1. Product Overview

The A8 Series NGS Workstation​ integrates online PCR and quantification modules to achieve full-process automation​ of library preparation.

2. Performance Data

Our automated workflow delivers superior yield and consistency compared to manual methods.

Fragment Analysis

The fragment distribution profile of the A8-NGS libraries is consistent with manual preparation, with the main peak concentrated between 200–300 bp.

3. Technical Specifications

Feature- Dimensions (W×D×H).                                        Throughput

A8Pro (Low Throughput)  790 × 740 × 980 mm​    1 – 24 samples

A8Pro (Mid Throughput) 1240 × 740 × 980 mm​    1 – 96 (or 48) samples

A8Plus (High Throughput) 1240 × 740 × 1168 mm​  1 – 96 samples

Robotic Pipetting

Principle:​ Air displacement
Volume:​ 1 μL – 1000 μL
Accuracy:​ ±4% @ 5 μL; ±1% @ 200 μL
Precision (CV):​ ≤4% @ 5 μL; ≤1% @ 200 μL
Liquid Level Detection:​ Pressure sensing

Safety & Biosafety

UV Sterilization:​ Dosage > 100,000 μW·s/cm²
HEPA Filter:​ Efficiency ≥ 99.99% @ 0.3 μm (ISO Class 5​ cleanroom standard)

Integrated PCR

Capacity:​ 96 wells
Speed:​ Heating ≥ 4°C/s; Cooling ≥ 2°C/s
Uniformity:​ ≤ 0.2°C
Accuracy:​ ≤ ±0.3°C

Built-in Quantification

Method:​ Fluorometric assay
Sensitivity:​ 0.01 ng/μL
Range:​ 0.1 – 120 ng/μL
Speed:​ ≤ 5 seconds/sample

Thermal Shaking

Temp. Range:​ 4°C – 120°C
Shaking Speed:​ Up to 3000 rpm
Positioning Accuracy:​ ±0.1 mm

4. Configurations

A8Plus High:​ Fixed 96-channel pipette + Flexible 4-channel + Gripper

A8Pro Mid:​ Fixed 24-channel pipette + Flexible 2-channel + Gripper

A8Pro Low:​ Fixed 8-channel pipette + Flexible 2-channel + Gripper

In-Situ Purification:​ Perform purification directly on PCR plates without tube transfer, reducing sample loss.

Pre-set Protocols:​ Ready-to-use templates minimize setup time.

One-Click Start:​ Supports direct loading of original sample tubes, simplifying the preparation workflow.

 Full automatic NGS Work flow             Video is available online 👇

A 8 Full automatic NGS workflow Robot

By Precision, For Simplicity

The A8 Series NGS Workstation​ integrates online PCR and quantification modules to achieve full-process automation​ of library preparation.

HLA Sanger Sequencing Technology

HLA SBT Typing Kit

Sanger Sequencing  HLA Typing Kits

Our product line covers:

  1. HLA Class II:​ Exon 1 through 3
  2. HLA Class I:​ Exon 1 through 5
  3. 3SP technology, which provides a definitive solution to eliminate phase ambiguity and ensure accurate allele assignment. 

We supply Sequence-Based Typing (SBT) HLA ​ high-resolution Typing kits. 

"Our automated SBT system streamlines the complex manual steps, significantly reducing hands-on time."

Automatic Nucleic Acid Purification 

Sanger sequencing automates the labor-intensive nucleic acid purification steps, effectively liberating technicians from repetitive manual tasks

This automation reduces operational costs and reagent consumption, while simultaneously minimizing human error​ to ensure consistent data quality.

utomated Sanger Sequencing Benefits:

Error Minimization:​ Eliminates variability caused by manual handling.

Cost Reduction:​ Lowers reagent costs and overall operational expenses.

Labor Saving:​ Automates complex nucleic acid cleanup, freeing up technician time.

Kir Gene Typing Kits NGS 

Next-Generation Sequencing for High-Resolution KIR Genotyping

Move beyond basic presence/absence testing with our targeted amplicon-based solution, purpose-built for advanced characterization of Killer-cell Immunoglobulin-like Receptor (KIR) genes — key regulators of NK cell function in transplantation, disease association, and immunology research.

Key Features

Comprehensive Locus Coverage: Captures all 14 functional KIR genes + 2 pseudogenes (KIR2DP1, KIR3DP1) across the chromosome 19q13.4 leukocyte receptor complex, spanning both inhibitory and activating loci.

Allele-Level Resolution: Detects gene content variation and fine-scale allelic diversity, including common variants of KIR2DL5, KIR2DS4, and KIR3DP1.

Flexible Configuration: Choose a full KIR gene panel or individual single-gene assays to match your lab’s throughput and research needs.

Streamlined NGS Workflow: Gene- and variant-specific primers enable efficient library prep with minimal optimization, compatible with standard short-read NGS pipelines.

Ideal For

Immunogenetics studies | Hematopoietic stem cell transplantation (HCT) research | NK cell biology | Population genetics & disease association studies

HLA NGS Typing Service 

HLA Typing Service 

HLA Typing Services

We provide high-resolution, deep sequencing HLA typing services tailored to your research and clinical needs.

Turnaround Time:​ We guarantee a rapid turnaround, delivering matched typing results within 5 business days.

Please contact us to request a quote​ or to discuss your specific project requirements."

Sanger Confirmation:Sanger Sequencing-based HLA typing​ is available for confirmatory and validation purposes.

Standard High-Res Typing:​ We offer comprehensive coverage of HLA Class I (Exon 1–5)​ and HLA Class II (Exon 1–3).

Custom Solutions:​ Upon request, we also provide-- 

   HLA Full-Length Gene Sequencing​ to capture all exons and introns.

 

Superior Biotechnology Meets laboratory Excellence

I hereby agree that this data will be stored and processed for the purpose of establishing contact. I am aware that I can revoke my consent at any time.*

*Please fill in all the required fields.
Message was successfully sent

Get in touch

E-mail: info@geno-code.com

whatsapp: +447404914814

Address : Suite G04, 1 Quality Court, Chancery Lane, 

                   London WC2A 1HR,  United Kingdom

© 2026 Geno-Code Bio. All rights reserved.

Information icon

We need your consent to load the translations

We use a third-party service to translate the website content that may collect data about your activity. Please review the details in the privacy policy and accept the service to view the translations.